Release FemLite 0.6.1
FemLite CI / build-test (push) Has been cancelled

This commit is contained in:
shenw
2026-07-01 22:41:16 +08:00
parent 175531e24d
commit 5e081806fb
32 changed files with 2819 additions and 238 deletions
+27
View File
@@ -121,6 +121,7 @@ src/interface C ABI 和 Fortran-C bridge
| `fem_contact_*` | contact pair 状态、目标、几何、搜索、摩擦、力、切线、mortar/AL、multiplier 和输出 |
| `fem_contact_multiplier` | mortar/AL 积分点乘子、trial/commit/rollback、restart 和 audit |
| `fem_contact_mortar_tangent` | 局部 mortar tangent、stick/slip 矩阵和 0.5.1 矩阵审计 |
| `fem_tangent_audit_report` | 共享 tangent audit CSV schema、状态词汇和覆盖计数;只做报告归一化 |
| `fem_output_csv` | 历史、节点、单元、反力和接触 CSV |
| `fem_output_vtk` | Legacy ASCII VTK 输出 |
| `fem_restart` | restart 读写 |
@@ -237,6 +238,9 @@ fem_contact_mortar_*.f90 mortar/AL 点更新、批处理、约束、迭代、报
- 0.5.1 起,`mortar_tan_audit_matrix` 用于检查局部 mortar tangent 的
row/column balance、刚体平移残差、非对称量和能量 probe。新增或修改
mortar tangent 公式时,应先扩展该审计和 `contact_mortar_tangent` 测试。
- 0.6.1 起,`fem_tangent_audit_report` 只提供统一 audit report schema、
`pass/fail/missing/not-applicable` 状态和覆盖计数;它不表示生产一致切线
或完整 AL/mortar tangent 已交付。
新增 contact pair 行为应覆盖:
@@ -612,3 +616,26 @@ When adding a new nonlinear owner state after 0.6.0:
them to claim delivery of complete AL/mortar consistent tangents,
mixed-control continuation, cohesive contact mainline, harmonic cyclic
nonzero-wave solving, DEM subcycling or production roll-forming workflows.
## 21. 0.6.1 Diagnostic Hardening Notes
0.6.1 diagnostic additions are append-only:
- `nonlinear_lifecycle.csv` extends lifecycle rows with cutback reason,
residual breakdown, linear solver method/preconditioner/iterations/status,
residuals and fail class.
- `contact_XXXXXXXX.csv` extends contact rows with stable state counters
(`open`, `closed-stick`, `closed-slip`, `closed-restick`, `separating`,
failed projection) plus gap/slip/friction residual summaries.
- `continuation_path.csv` extends path rows with `arc_mode`,
predictor-consistency, load-reversal, turning-point, arc-length and load
delta fields. These are diagnostics only and do not introduce
mixed-control continuation.
- `fem_tangent_audit_report` provides a shared report vocabulary for existing
tangent audits and missing/not-applicable coverage counters. It is not a
production consistent-tangent implementation.
- Restart tests should compare lifecycle/contact/path summaries before and
after read-back when those summaries are supported by the compact model.
Keep larger algorithm rewrites deferred unless a later development plan
explicitly schedules them.