Complete V5 acceptance milestone
This commit is contained in:
@@ -0,0 +1,33 @@
|
||||
# Euler Column Buckling Benchmark
|
||||
|
||||
This benchmark verifies the V5 linear buckling path on a pinned-pinned
|
||||
Euler-Bernoulli column with a known analytical critical load:
|
||||
|
||||
```text
|
||||
Pcr = pi^2 E I / (K L)^2
|
||||
```
|
||||
|
||||
The benchmark tool assembles the beam bending stiffness and calls the production
|
||||
`geom_beam2d_column_stiffness`, `buckling_dense_solve` and
|
||||
`buckling_euler_column_load` routines from `femlite_core`.
|
||||
|
||||
Files:
|
||||
|
||||
- `euler_column_buckling.inp`: benchmark input with `E`, `I`, `L`, element
|
||||
count and effective length factor.
|
||||
- `check_buckling_results.py`: CTest checker.
|
||||
- `run_case.bat`: double-click runner.
|
||||
|
||||
Generated outputs:
|
||||
|
||||
- `buckling_summary.csv`: Euler reference, computed first three load factors,
|
||||
residual, relative error and KG mode normalization.
|
||||
- `buckling_mode_1.csv`: first-mode transverse displacement and rotation by
|
||||
column node.
|
||||
|
||||
Acceptance:
|
||||
|
||||
- First buckling load relative error must be at most `2.0e-2`.
|
||||
- First modal residual must be at most `1.0e-8`.
|
||||
- The first mode must be normalized such that `phi^T KG phi = 1`.
|
||||
- Pinned-end transverse displacement must remain zero.
|
||||