Layered Shell Failure Prediction Smoke Case

This folder contains the original layered-shell failure benchmark notes plus a compact FemLite smoke case:

  • layered_shell_tension_smoke.inp
  • run_case.bat

The reference problem uses orthotropic composite plies, rotated material systems, polynomial failure criteria, failure indices, and safety factors. FemLite V4.8 does not claim that full composite failure workflow. The included input keeps the executable structural skeleton: four coincident S4 plies sharing the same midsurface nodes, ply-scale thicknesses, benchmark-style nodal constraints, and the in-plane tensile edge load.

Run:

run_case.bat

Results are written to results\auto_run.