1.5 KiB
1.5 KiB
Euler Column Buckling Benchmark
This benchmark verifies the V5 main-solver linear buckling path on a pinned-pinned Euler-Bernoulli column with a known analytical critical load:
Pcr = pi^2 E I / (K L)^2
The default example path runs:
build-win-gcc-16\femlite.exe examples\euler_column_buckling\euler_column_buckling.inp --buckling --output-dir examples\euler_column_buckling\results\auto_run
The main executable reads *BUCKLING COLUMN, assembles the column through
fem_buckling_column, and calls the production geom_beam2d_column_stiffness,
buckling_dense_solve and buckling_euler_column_load routines from
femlite_core. The legacy benchmark executable is only a thin wrapper around the
same production module.
Files:
euler_column_buckling.inp: benchmark input withE,I,L, element count and effective length factor.check_buckling_results.py: CTest checker for thefemlite --bucklingworkflow.run_case.bat: double-click runner that builds and callsfemlite.
Generated outputs:
buckling_summary.csv: Euler reference, computed first three load factors, residual, relative error and KG mode normalization.buckling_mode_1.csv: first-mode transverse displacement and rotation by column node.
Acceptance:
- First buckling load relative error must be at most
2.0e-2. - First modal residual must be at most
1.0e-8. - The first mode must be normalized such that
phi^T KG phi = 1. - Pinned-end transverse displacement must remain zero.