Files
FemLite/examples/spherical_cap_with_central_point_load

Spherical Cap Central Point Load Benchmark

This folder contains a displacement-control FemLite benchmark derived from models.sme.spherical_cap_with_central_point_load.pdf:

  • generate_spherical_cap.py
  • spherical_cap_displacement_control.inp
  • spherical_cap_displacement_control_shell4.inp
  • check_spherical_cap_results.py
  • run_case.bat

The reference model is the NAFEMS spherical cap postbuckling case: radius a = 10 m, thickness th = 0.203840 m, E = 210 GPa, nu = 0.3, cap angle pi/4, rim support, and crown displacement control. The Shell-16 baseline keeps the documented polar topology with a crown S3 fan and S4 meridional bands, uses the historical full-rim constraint (RIM_DOF_MAX=6), and explicitly requests SHELL_GEOMETRIC=LINEAR. The Shell-4 finite-strain target uses the same geometry and material scale, but replaces the crown fan with an all-quadrilateral square-to-disk S4 remesh so that it can enter the V5.11 SHELL_GEOMETRIC=FINITE_STRAIN production path. Its rim support intentionally constrains translations only (RIM_DOF_MAX=3) to match the PDF shell point/rim-support interpretation used by the diagnostic decks; full rotational rim clamping is not the Shell-4 postbuckling benchmark target because it masks the observed load drop. Both decks prescribe the crown displacement to -6.2 m; the reaction is nondimensionalized as

Fn = -F*a/(E*th^3*2*pi), wn = -w/th

FemLite currently checks the displacement-control shell path that its small-strain shell formulation can support. By default, the checker runs static-linear Shell-16 samples at the PDF table displacement values and writes spherical_cap_load_displacement.csv. If the environment variable FEMLITE_SPHERICAL_CAP_NONLINEAR=1 is set, the checker instead attempts a real --static-nonlinear Shell-4 direct-displacement path over the bounded V5.11 post-peak window and validates continuation_path.csv, the translational rim support, path-control diagnostics and a reproducible load drop after the first peak. The bounded nonlinear route defaults to uz=-3.24 m; it can be changed with FEMLITE_SPHERICAL_CAP_BOUNDED_UZ.

If FEMLITE_SPHERICAL_CAP_RIKS=1 is set, the checker runs a separate load-control Shell-4 Riks route. It converts the crown control to a proportional crown CLOAD, writes spherical_cap_riks_load_path.csv, and validates that the load parameter reaches a real limit-point neighborhood and decreases after the peak while displacement continues to grow. This is a method-4 load-type Riks evidence route for a real post-limit branch segment; broader branch-following generalization is still deferred.

V5.11 uses this example as a finite-strain S4 capability proof, not as a claim that the full uz=-6.2 m PDF curve has been strictly reproduced. Full Shell-4/8/16 digitized-curve matching, later restiffening-window tuning and late post-peak performance optimization are deferred to the next version.

Run:

run_case.bat

Results are written to results\auto_run.

Important output files:

  • continuation_path.csv: production accepted-increment direct displacement path, present only when the optional nonlinear diagnostic route completes.
  • spherical_cap_load_displacement.csv: checker-derived nondimensional wn = -w/th and Fn = -F*a/(E*th^3*2*pi) curve.
  • spherical_cap_riks_load_path.csv: optional load-control Riks path, present only when FEMLITE_SPHERICAL_CAP_RIKS=1 completes.