Euler Column Buckling Benchmark

This benchmark verifies the V5 linear buckling path on a pinned-pinned Euler-Bernoulli column with a known analytical critical load:

Pcr = pi^2 E I / (K L)^2

The benchmark tool assembles the beam bending stiffness and calls the production geom_beam2d_column_stiffness, buckling_dense_solve and buckling_euler_column_load routines from femlite_core.

Files:

  • euler_column_buckling.inp: benchmark input with E, I, L, element count and effective length factor.
  • check_buckling_results.py: CTest checker.
  • run_case.bat: double-click runner.

Generated outputs:

  • buckling_summary.csv: Euler reference, computed first three load factors, residual, relative error and KG mode normalization.
  • buckling_mode_1.csv: first-mode transverse displacement and rotation by column node.

Acceptance:

  • First buckling load relative error must be at most 2.0e-2.
  • First modal residual must be at most 1.0e-8.
  • The first mode must be normalized such that phi^T KG phi = 1.
  • Pinned-end transverse displacement must remain zero.