Euler Column Buckling Benchmark
This benchmark verifies the V5 linear buckling path on a pinned-pinned Euler-Bernoulli column with a known analytical critical load:
Pcr = pi^2 E I / (K L)^2
The benchmark tool assembles the beam bending stiffness and calls the production
geom_beam2d_column_stiffness, buckling_dense_solve and
buckling_euler_column_load routines from femlite_core.
Files:
euler_column_buckling.inp: benchmark input withE,I,L, element count and effective length factor.check_buckling_results.py: CTest checker.run_case.bat: double-click runner.
Generated outputs:
buckling_summary.csv: Euler reference, computed first three load factors, residual, relative error and KG mode normalization.buckling_mode_1.csv: first-mode transverse displacement and rotation by column node.
Acceptance:
- First buckling load relative error must be at most
2.0e-2. - First modal residual must be at most
1.0e-8. - The first mode must be normalized such that
phi^T KG phi = 1. - Pinned-end transverse displacement must remain zero.