Files
FemLite/examples/blasting_rock/blasting_rock_pulse_smoke.inp
T
shenw 8f9c1ece61
FemLite CI / build-test (push) Has been cancelled
Complete V4.8 hardening and examples coverage
2026-06-25 11:27:59 +08:00

39 lines
828 B
Plaintext

*HEADING
FemLite V4.8 compact blasting-rock pulse smoke case
** Reference scale: H=L=0.24 m, E=50 GPa, nu=2/7, rho=2700 kg/m3.
** Low-reflecting boundaries and FFT postprocessing are outside the V4.8 scope.
*NODE
1, 0.00, 0.00, 0.00
2, 0.24, 0.00, 0.00
3, 0.24, 0.24, 0.00
4, 0.00, 0.24, 0.00
5, 0.00, 0.00, 0.24
6, 0.24, 0.00, 0.24
7, 0.24, 0.24, 0.24
8, 0.00, 0.24, 0.24
*ELEMENT, TYPE=C3D8, ELSET=ROCK
1, 1, 2, 3, 4, 5, 6, 7, 8
*NSET, NSET=XSYM
1, 4, 5, 8
*NSET, NSET=YSYM
1, 2, 5, 6
*NSET, NSET=BLAST_PATCH
1
*MATERIAL, NAME=GRANITE
*DENSITY
2700.0
*ELASTIC
5.0E10, 0.285714285714
*SOLID SECTION, ELSET=ROCK, MATERIAL=GRANITE
*BOUNDARY
XSYM, 1, 1, 0.0
YSYM, 2, 2, 0.0
*AMPLITUDE, NAME=BLAST_PULSE
0.0, 0.0, 1.0E-5, 1.0, 8.1E-5, 0.0
*CLOAD, AMPLITUDE=BLAST_PULSE
BLAST_PATCH, 3, 1.4E6
*STEP
*DYNAMIC
1.0E-6, 1.5E-4
*END STEP