# 07 真实 Worker 最小接入审计
## 1. 审计结论
CCLite 0.1.10 已将真实 worker 审计从“参数是否存在”升级为“能力查询、真实 IPC attach 行为和协议对齐状态”三层检查。
当前结论为:
```text
EXTERNAL_WORKERS_READY_CCLITE_PROTOCOL_ADAPTER_REQUIRED
```
含义是:
1. 当前 SPHLite 包已提供 `--cclite-capabilities`,并报告 `cclite_worker=yes`、`supports_real_ipc=yes`、`supports_sph_to_ccl_particle=yes` 和 `supports_ccl_to_sph_force=yes`。
2. 当前 FEMLite 包已提供 `--cclite-capabilities`,并报告 `cclite_worker=yes`、`worker_mock=yes`、`supports_real_ipc=yes`、`supports_fem_to_ccl_facet=yes` 和 `supports_ccl_to_fem_load=yes`。
3. 两个 worker 在没有 CCLite 预创建 IPC 资源时都会尝试打开真实 IPC,并返回可识别的 attach/open 失败,而不是旧版本的参数缺失或未实现。
4. FEMLite worker mock 仍可运行,当前输出为 `CCLite worker completed: mock`。
5. CCLite 0.1.10 尚不声明真实外部 SPHLite/FEMLite 进程联调完成,因为 FEMLite 发布的 IPC 结构和命名规则与 CCLite 0.1.x 当前通用 command/data block 不完全一致,仍需要 CCLite 侧协议/命名 adapter 和进程级 gate。
## 2. CCLite 固化的 worker 参数
真实 worker 应至少支持:
```text
<solver.exe> --cclite-worker --solver-id <SPH|FEM> --case <solver.inp> --ipc-name <prefix> --timeout-ms <milliseconds>
```
CCLite 0.1.10 启动 worker 时还会补充新版求解器可识别的辅助参数:
```text
--command-block <name>
--data-prefix <prefix>
--worker-id <SPH|FEM>
```
FEMLite worker 额外使用:
```text
--worker-backend ipc
```
这些参数用于补齐启动契约;它们不代表二进制协议已经自动兼容。
## 3. 当前真实 worker 审计结果
本地审计命令由 `Python/checkers/audit_real_workers.py` 执行,并生成:
```text
build-codex-gcc/output/real_worker_gap_report.json
```
当前审计报告包含:
1. `sphlite_capabilities`:SPHLite 能力查询;
2. `femlite_capabilities`:FEMLite 能力查询;
3. `sphlite_standard_ipc`:SPHLite 标准 worker 参数 attach 探测;
4. `femlite_standard_ipc`:FEMLite 标准 worker 参数 attach 探测;
5. `femlite_explicit_ipc_backend`:FEMLite `--worker-backend ipc` attach 探测;
6. `femlite_worker_mock`:FEMLite 自运行 worker mock 探测;
7. `protocol_alignment`:CCLite 当前协议与外部 worker 已发布协议的对齐状态。
SPHLite 标准 IPC worker 探测当前应表现为:
```text
status: IPC_ATTACH_ATTEMPTED
recognized_worker_cli: true
real_ipc_attach_attempted: true
```
FEMLite 标准 IPC worker 探测当前应表现为:
```text
status: IPC_ATTACH_ATTEMPTED
recognized_worker_cli: true
real_ipc_attach_attempted: true
```
FEMLite worker mock 探测当前应表现为:
```text
status: WORKER_MOCK_AVAILABLE
```
## 4. 协议对齐状态
CCLite 0.1.x 当前内部协议为:
```text
command block: CCLite generic command block v1
data header: CCLite generic data block header v0.1
control name: <prefix>_CCL_COMMAND_<solver>
event names: <prefix>_EVENT_COMMAND_<solver>, <prefix>_EVENT_ACK_<solver>
data names: <prefix>_<ROLE>
```
SPHLite 当前文档中的默认命名为:
```text
<ipc_name>.command
<ipc_name>.command_event
<ipc_name>.done_event
```
SPHLite 支持 `--command-block` 和 `--data-prefix` 覆盖部分名称,但真实外部 CCLite 进程联调仍需要 CCLite 侧 adapter gate 验收。
FEMLite 当前发布的真实 IPC worker 使用:
```text
<prefix>_COMMAND_BLOCK
<prefix>_COMMAND_EVENT
<prefix>_DONE_EVENT
<data-prefix>_FEM_TO_CCL_FACET
<data-prefix>_CCL_TO_FEM_LOAD
```
并在 `FEMLite/cpu_release/include/femlite_cclite_ipc.h` 中发布了 `femlite_cclite_command_block` 与 `femlite_cclite_data_header`。该结构与 CCLite 0.1.x 当前通用 block 不是同一二进制布局,因此 CCLite 后续必须增加外部协议 adapter 或统一 05 号接口控制文档中的二进制契约。
## 5. 0.1.10 验收口径
0.1.10 完成以下工程目标:
1. CCLite 可自动读取 SPHLite/FEMLite 的 `--cclite-capabilities` 输出;
2. 真实 worker attach 失败被识别为 `IPC_ATTACH_ATTEMPTED`,不再误判为参数缺失或未实现;
3. FEMLite 新版 mock 输出 `CCLite worker completed: mock` 被识别为 `WORKER_MOCK_AVAILABLE`;
4. 审计报告明确输出 `CCLITE_PROTOCOL_ADAPTER_REQUIRED`;
5. CCLite 主控启动 worker 时补充 `--command-block`、`--data-prefix`、`--worker-id`,FEMLite 补充 `--worker-backend ipc`;
6. 0.1.x 可执行验收路径仍由 CCLite 内置 mock worker 完成;
7. 真实 SPH-FEM 接触力、真实外部双 worker 联调、摩擦、FSI 和 Linux/MPI 不在 0.1.10 中声明完成。
## 6. 后续接入条件
进入真实外部 worker 空耦合前,CCLite 侧必须完成:
1. 明确采用统一 CCLite 05 号通用 block,还是为 SPHLite/FEMLite 各自协议增加 adapter;
2. 建立 `真实 SPHLite + mock FEM` 的 1 step 和 100 step 空耦合 gate;
3. 建立 `mock SPH + 真实 FEMLite` 的 1 step 和 100 step 空耦合 gate;
4. 建立 `真实 SPHLite + 真实 FEMLite` 的 1 step 和 100 step 空耦合 gate;
5. 将能力查询、协议版本、record stride、block 容量和错误码纳入自动报告;
6. 在上述 gate 通过前,不把 `supports_real_ipc=yes` 解释为真实外部联调完成。