# 07 真实 Worker 最小接入审计
|
||
|
||
## 1. 审计结论
|
||
|
||
CCLite 0.2.9 将真实 worker 审计提升为 `V020_SINGLE_REAL_WORKER_SMOKE` gate。该 gate 的目的不是声明真实 SPHLite/FEMLite 外部进程物理联调完成,而是确认当前 worker 能力、统一入口、协议差异和后续 adapter 缺口。
|
||
|
||
当前结论为:
|
||
|
||
```text
|
||
EXTERNAL_WORKERS_READY_CCLITE_PROTOCOL_ADAPTER_REQUIRED
|
||
gate_status: CONTROLLED_PROTOCOL_GAP
|
||
```
|
||
|
||
含义如下:
|
||
|
||
1. SPHLite 已提供 `--cclite-capabilities`,并报告 `cclite_worker=yes`、`supports_real_ipc=yes`、`supports_sph_to_ccl_particle=yes`、`supports_ccl_to_sph_force=yes`。
|
||
2. FEMLite 已提供 `--cclite-capabilities`,并报告 `cclite_worker=yes`、`worker_mock=yes`、`supports_real_ipc=yes`、`supports_fem_to_ccl_facet=yes`、`supports_ccl_to_fem_load=yes`。
|
||
3. 两个 worker 在没有 CCLite 预创建 IPC 资源时均会尝试打开真实 IPC,并返回可识别的 attach/open 失败,而不是参数缺失或未实现。
|
||
4. CCLite 0.2.9 选择“混合过渡”策略:CCLite 内部继续使用 05 号接口文档定义的通用 command/data block;真实 SPHLite/FEMLite 外部边界通过求解器专用 adapter 对齐命名、二进制布局、payload 和错误码。
|
||
5. 在 adapter 的进程级测试通过前,真实 worker gate 输出 `CONTROLLED_PROTOCOL_GAP`,mock worker 仍是 0.2.x 基础接触算法的可执行验收路径。
|
||
|
||
## 2. 固化的 worker 入口
|
||
|
||
真实 worker 至少应支持:
|
||
|
||
```text
|
||
<solver.exe> --cclite-worker --solver-id <SPH|FEM> --case <solver.inp> --ipc-name <prefix> --timeout-ms <milliseconds>
|
||
```
|
||
|
||
CCLite 启动 worker 时还会补充新版求解器可识别的辅助参数:
|
||
|
||
```text
|
||
--command-block <name>
|
||
--data-prefix <prefix>
|
||
--worker-id <SPH|FEM>
|
||
```
|
||
|
||
FEMLite worker 额外使用:
|
||
|
||
```text
|
||
--worker-backend ipc
|
||
```
|
||
|
||
这些参数只说明启动入口已经统一,不代表二进制通信协议已经完全兼容。
|
||
|
||
## 3. Adapter 策略
|
||
|
||
0.2.9 确认采用:
|
||
|
||
```text
|
||
HYBRID_GENERIC_BLOCK_PLUS_SOLVER_ADAPTER
|
||
```
|
||
|
||
策略说明:
|
||
|
||
1. CCLite 内部契约保持统一:generic command block v1、generic data block header、AoR v1 payload、CCLite 负责资源创建和销毁。
|
||
2. 外部真实 worker 边界增加求解器专用 adapter:SPHLite adapter 主要处理命名和 command/data 对齐;FEMLite adapter 还必须处理已发布的 native compact header。
|
||
3. 不采用“只按求解器协议分叉”的原因是 controller、mock worker、诊断和接触算法已经共享同一套 CCLite 数据模型,分叉会复制校验逻辑。
|
||
4. 不在 0.2.9 直接声明“通用 block 已接通”的原因是当前外部 worker 发布的对象命名和至少 FEMLite 的二进制 header 与 CCLite generic block 不一致。
|
||
|
||
后续 adapter 必须覆盖:
|
||
|
||
1. command block name、command event、done/ack event 映射;
|
||
2. command id、seq/ack、worker state 和 error code 映射;
|
||
3. data header magic、version、layout、role、stride、capacity 映射;
|
||
4. 空 payload 和可控 payload 的读取校验;
|
||
5. 空 load block 和可控 load block 的 `IMPORT_LOADS` 导入校验;
|
||
6. timeout、异常退出和资源释放映射。
|
||
|
||
## 4. 当前审计结果
|
||
|
||
本地审计命令由 `Python/checkers/audit_real_workers.py` 执行,并生成:
|
||
|
||
```text
|
||
build-codex-gcc/output/real_worker_gap_report.json
|
||
```
|
||
|
||
0.2.9 还增加 gate checker:
|
||
|
||
```text
|
||
Python/checkers/check_v020_real_worker_gate.py
|
||
build-codex-gcc/output/v020_real_worker_gate/verification_report.json
|
||
```
|
||
|
||
当前报告包含:
|
||
|
||
1. `adapter_strategy`:CCLite adapter 策略;
|
||
2. `worker_capability_summary`:worker 名称、版本探测、IPC 能力、block 能力和缺口状态;
|
||
3. `sphlite_standard_ipc`:SPHLite 标准 worker 参数 attach 探测;
|
||
4. `femlite_standard_ipc`:FEMLite 标准 worker 参数 attach 探测;
|
||
5. `femlite_explicit_ipc_backend`:FEMLite `--worker-backend ipc` attach 探测;
|
||
6. `femlite_worker_mock`:FEMLite 自运行 worker mock 探测;
|
||
7. `protocol_alignment`:CCLite 当前协议与外部 worker 已发布协议的对齐状态;
|
||
8. `v020_adapter_gate`:0.2.9 单真实 worker gate 的逐项结果。
|
||
|
||
SPHLite 标准 IPC worker 探测当前应表现为:
|
||
|
||
```text
|
||
status: IPC_ATTACH_ATTEMPTED
|
||
recognized_worker_cli: true
|
||
real_ipc_attach_attempted: true
|
||
```
|
||
|
||
FEMLite 标准或显式 IPC worker 探测当前应表现为:
|
||
|
||
```text
|
||
status: IPC_ATTACH_ATTEMPTED
|
||
recognized_worker_cli: true
|
||
real_ipc_attach_attempted: true
|
||
```
|
||
|
||
FEMLite worker mock 探测当前应表现为:
|
||
|
||
```text
|
||
status: WORKER_MOCK_AVAILABLE
|
||
```
|
||
|
||
## 5. 协议对齐状态
|
||
|
||
CCLite 0.2.x 当前内部协议为:
|
||
|
||
```text
|
||
command block: CCLite generic command block v1
|
||
data header: CCLite generic data block header
|
||
control name: <prefix>_CCL_COMMAND_<solver>
|
||
event names: <prefix>_EVENT_COMMAND_<solver>, <prefix>_EVENT_ACK_<solver>
|
||
data names: <prefix>_<ROLE>
|
||
```
|
||
|
||
SPHLite 当前默认命名为:
|
||
|
||
```text
|
||
<ipc_name>.command
|
||
<ipc_name>.command_event
|
||
<ipc_name>.done_event
|
||
```
|
||
|
||
SPHLite 已支持 `--command-block` 和 `--data-prefix` 覆盖部分名称,但仍需要 CCLite adapter gate 验证完整 command/data 行为。
|
||
|
||
FEMLite 当前真实 IPC worker 使用:
|
||
|
||
```text
|
||
<prefix>_COMMAND_BLOCK
|
||
<prefix>_COMMAND_EVENT
|
||
<prefix>_DONE_EVENT
|
||
<data-prefix>_FEM_TO_CCL_FACET
|
||
<data-prefix>_CCL_TO_FEM_LOAD
|
||
```
|
||
|
||
并在 `FEMLite/cpu_release/include/femlite_cclite_ipc.h` 中发布 `femlite_cclite_command_block` 和 `femlite_cclite_data_header`。这些结构与 CCLite 0.2.x 当前 generic block 不是同一二进制布局,因此必须增加外部协议 adapter 或统一 05 号接口控制文档中的二进制契约。
|
||
|
||
## 6. 0.2.9 Gate 结果
|
||
|
||
Gate 编号:
|
||
|
||
```text
|
||
V020_SINGLE_REAL_WORKER_SMOKE
|
||
```
|
||
|
||
| 路径 | 当前状态 | 说明 |
|
||
| --- | --- | --- |
|
||
| 真实 SPHLite + mock FEMLite,1 step 空耦合 | `CONTROLLED_PROTOCOL_GAP` | SPHLite 可识别 worker CLI 并尝试真实 IPC attach,但 CCLite 尚未执行命名和 block adapter |
|
||
| mock SPHLite + 真实 FEMLite,1 step 空耦合 | `CONTROLLED_PROTOCOL_GAP` | FEMLite 可识别 worker CLI 并尝试真实 IPC attach,但 native header 和命名与 CCLite generic block 不一致 |
|
||
| 单真实 worker,100 step 空耦合 | `CONTROLLED_PROTOCOL_GAP` | 依赖至少一条 1 step adapter 路径通过;当前不声明 seq/ack、timeout 或资源释放已验证 |
|
||
| 真实 worker payload 读取 smoke | `CONTROLLED_PROTOCOL_GAP` | 真实 worker export header 尚未映射为 CCLite generic data header,stride/role/step 无法由当前 reader 验证 |
|
||
| 真实 worker load import smoke | `CONTROLLED_PROTOCOL_GAP` | 真实 worker load header 尚未由 CCLite generic load block 映射,`IMPORT_LOADS` 响应未进入进程级验证 |
|
||
|
||
`CONTROLLED_PROTOCOL_GAP` 是 0.2.9 的可接受 gate 结果,前提是报告必须列出 worker 能力、已探测行为和阻塞字段。该状态不等价于真实 SPH-FEM 外部进程物理联调完成。
|
||
|
||
## 7. 后续接入条件
|
||
|
||
进入真实外部 worker 空耦合前,CCLite 侧必须完成:
|
||
|
||
1. SPHLite 命名和 command/data adapter;
|
||
2. FEMLite native header 和命名 adapter;
|
||
3. `真实 SPHLite + mock FEMLite` 的 1 step 和 100 step 空耦合 gate;
|
||
4. `mock SPHLite + 真实 FEMLite` 的 1 step 和 100 step 空耦合 gate;
|
||
5. 真实 worker payload header、role、layout、record stride、step id 校验;
|
||
6. 真实 worker 空 load 或可控 load 的 `IMPORT_LOADS`、`ADVANCE`、`STOP` 校验;
|
||
7. 资源释放、timeout、异常退出和残留进程检查。
|
||
|
||
在上述 gate 通过前,`supports_real_ipc=yes` 只能解释为 worker 具备真实 IPC 后端能力,不能解释为 CCLite 与真实 SPHLite/FEMLite 的完整进程级耦合已完成。
|