# Euler Column Buckling Benchmark
This benchmark verifies the V5 main-solver linear buckling path on a pinned-pinned
Euler-Bernoulli column with a known analytical critical load:
```text
Pcr = pi^2 E I / (K L)^2
```
The default example path runs:
```powershell
build-win-gcc-16\femlite.exe examples\euler_column_buckling\euler_column_buckling.inp --buckling --output-dir examples\euler_column_buckling\results\auto_run
```
The main executable reads `*BUCKLING COLUMN`, assembles the column through
`fem_buckling_column`, and calls the production `geom_beam2d_column_stiffness`,
`buckling_dense_solve` and `buckling_euler_column_load` routines from
`femlite_core`. The legacy benchmark executable is only a thin wrapper around the
same production module.
Files:
- `euler_column_buckling.inp`: benchmark input with `E`, `I`, `L`, element
count and effective length factor.
- `check_buckling_results.py`: CTest checker for the `femlite --buckling`
workflow.
- `run_case.bat`: double-click runner that builds and calls `femlite`.
Generated outputs:
- `buckling_summary.csv`: Euler reference, computed first three load factors,
residual, relative error and KG mode normalization.
- `buckling_mode_1.csv`: first-mode transverse displacement and rotation by
column node.
Acceptance:
- First buckling load relative error must be at most `2.0e-2`.
- First modal residual must be at most `1.0e-8`.
- The first mode must be normalized such that `phi^T KG phi = 1`.
- Pinned-end transverse displacement must remain zero.