# Two Arches Contact Benchmark
This folder contains the reference two-arches notes and a FemLite benchmark
input derived from `models.sme.two_arches.pdf`:
- `two_arches_benchmark.inp`
- `check_two_arches_results.py`
- `run_case.bat`
The model uses the published geometry parameters: upper radius 80 mm, lower
radius 100 mm, shell width/thickness 3 mm, upper segment 80 degrees, lower
segment 100 degrees, 30 mapped upper shell elements, and 75 mapped lower shell
elements. The two arches are modeled with frictionless shell contact.
The original reference uses a stationary continuation study, a global equation,
and a load parameter to trace the postcritical response. FemLite does not yet
provide that full continuation solver. This benchmark therefore emulates the
first continuation increment by prescribing the upper midpoint displacement
`60 mm * 0.02 = 1.2 mm` over two explicit micro-steps, while preserving the
reference geometry, materials, mesh density, shell contact, lower end fixity,
upper end in-plane constraints, and out-of-plane plane-strain suppression.
The micro-step time scale is numerical only; it avoids dynamic overshoot and
does not represent the stationary postcritical continuation path.
Run:
```bat
run_case.bat
```
Results are written to `results\auto_run`. The checker verifies node and
element counts, key reference coordinates, the prescribed upper midpoint
displacement, active contact output, and a millimeter-scale displacement bound
so accidental dynamic blow-up is caught.